Abstract
Reinforcement bending reinforced concrete structures by increasing the cross section and assessing the load-bearing capacity of the inclined section such elements is an urgent problem, as not yet accumulated adequate research data on the stress-strain state such structures in the span, which works on shear and shear bending moment and transverse force. Analyzing the development theories calculation reinforced concrete elements inclined to the longitudinal axis, we can identify many areas, the main approach of which was based on the calculation using the bases of material resistance, and the use of empirical dependencies. Theoretical approaches calculation the European construction magazine RILEM TC, SNiP 2.03.01.-84* are considered, DBN B.2.6-98 2009 (Eurocode 2), US ACI 318-19. Experimental studies reinforced concrete elements to determine the load-bearing capacity inclined sections were performed on the basis of 5 samples reinforced concrete beams, 14 reinforced samples of reinforced concrete and shotcrete a total of 19 pieces in four series. Beams were made of concrete in each series fck = 19.08 MPa; fck = 27.74 MPa; fck = 20.48 MPa; fck = 20.48 MPa, respectively, reinforced samples with concrete fck = 17.95 MPa; fck = 19.5 MPa (shotcrete fck = 31.00 MPa); shotcrete fck = 19.9 MPa; fck = 19.9 MPa. Also for the manufacture and reinforcement beams used flat and U-shaped frames with working longitudinal reinforcement Ø22, Ø16, Ø12, Ø10, Ø6 A400C, and transverse reinforcement Ø6 A240C (step 120 mm). Reinforcement inclined sections of the experimental beams was performed on one, two or three sides, depending on the variant of the sample and the type of frame flat or U-shaped. Investigations of beams were performed according to the static scheme - a beam on two supports, span L=2100 mm. Deformations of concrete and reinforcement in the samples when determining the bearing capacity of inclined sections were measured using microindicators of the clock type, strain gauges. According to the results theoretical and experimental studies the bearing capacity inclined sections to the longitudinal axis, we can see a significant reassessment between the theoretical values inclined sections according to the new DBN B.2.6.-98: 2009 (Eurocode 2) over the actual results obtained during testing samples 53-67% for conventional beams, and 27-50% for reinforced beams. The results US regulations ACI 318-19 showed convergence of results in the range of 2-9% for samples without reinforcement and 1-7% for samples with reinforcement, but the values show the excess of experimental data over theoretical, indicating the impossibility of accurately determining the actual final bearing capacity. The results the calculation obtained by the method of SNiP 2.03.01-84*, both unreinforced and reinforced beams has a satisfactory agreement with the experimental values in the range of 6-10%.
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have