Abstract
The resist materials are evaluated using their resolution, line edge roughness (LER), and sensitivity. However, the evaluation of chemically amplified resists is tricky because of the trade-off relationships between resolution, LER, and sensitivity. In this study, we investigated a chemically amplified resist with a fullerene matrix by analyzing the dose-pitch matrices of line width and LER. The effective quencher concentration of the fullerene resist obtained by the analysis was higher than those of typical polymer-type resists. This suggests that the quantum efficiency of acid generation in the fullerene matrix is slightly lower than those of polymer-type resists. The effective reaction radius was 0.06 nm, which was smaller than those of polymer-type resists. The proportionality constant between LER and the chemical gradient of the fullerene resist was smaller than those of polymer-type resists, probably owing to its molecular size.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.