Abstract
AbstractAn alternative to industrial X-ray film for Industrial radiography is described. The experimental system uses film containing approximately 35%, of the silver in an industrial type film, which makes the film easier to process, and uses high resolution phosphor screens, which improves the absorption of X-ray photons. Those properties that affect image quality, namely contrast, modulation transfer function and granularity, are discussed in detail for both types of system. A study of low contrast detail in radiographs indicates that for noise limited information the experimental system offers a higher image quality than industrial X-ray film of similar speed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.