This study aims to evaluate the planned dose of stereotactic body radiation therapy (SBRT) for treating early peripheral non-small cell lung cancer (NSCLC) using the non-coplanar radiation from Cyberknife and Varian linac. Moreover, this study investigates whether Cyberknife and Varian linac are qualified for non-coplanar radiation SBRT for treating early peripheral NSCLC, and which one is better for protecting organs at risk (OARs). Retrospective analysis was performed based on the Cyberknife radiation treatment plans (RTPs) and Varian Eclipse RTPs of 10 patients diagnosed with early peripheral NSCLC. The dose distributions in the target and OARs were compared between the RTPs of Cyberknife and Varian Eclipse using Mim medical imaging software. For PTV, no significant difference in D98 and D95 between the Cyberknife and Eclipse was observed (t = -0.35, -1.67, P > 0.05). The homogeneity indexes (HIs) of Cyberknife plans are higher (t = 71.86, P < 0.05) than those of Eclipse plans. The V10, V15, V20, V25, V30 and Dmean of the lung with NSCLC and the V20 of the whole lung for Cyberknife were less than those for Eclipse (t = -4.73, -5.62, -7.75, -6.38, -6.89, -3.14, -7.09, respectively, P < 0.05). Cyberknife plans have smaller spinal cord Dmax, trachea Dmax, heart Dmax, chest wall Dmax (t = -2.49, -2.57, -3.71, -3.56, respectively, P < 0.05) and esophagus Dmax (t = -1.95, P > 0.05) than Varian Eclipse plans. To fulfill SBRT by non-coplanar radiation, Cyberknife is recommended for the institutions equipped with Cyberknife, while Varian linac can be applied for the institutions that have not adopted Cyberknife in clinical radiotherapyyet.