Abstract

The incorporation of noncoplanar beam arrangements has been proposed in liver radiotherapy modalities, which can reduce the dose in normal tissues compared to coplanar techniques. Noncoplanar radiotherapy techniques for hepatocellular carcinoma treatment based on the Linac design have a limited effective arc angle to avoid collisions. To propose a novel noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system and investigate its performance in hepatocellular carcinoma patients. The computed tomography was deflected 90° to meet the structure of a cage-like radiotherapy system and design the noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system plan in the Pinnacle3 planning system. An noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system plan was customized for each of 10 included hepatocellular carcinoma patients, with 6 dual arcs ranging from -30° to 30°. Six couch angles were set with an interval of 36° and distributed along with the longest diameter of planning target volume. The dosimetric parameters of noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system plan were compared with the noncoplanar volumetric modulated arc therapy and volumetric modulated arc therapy plan. The 3 radiotherapy techniques regarding planning target volume were statistically different for D98%, D2%, conformity index, and homogeneity index with χ2 = 9.692, 14.600, 8.600, and 12.600, and P = .008, .001, .014, and .002, respectively. Further multiple comparisons revealed that noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system significantly reduced the mean dose (P = .005) and V5 (P = .005) of the normal liver, the mean dose (P = .005) of the stomach, and V30 (P = .028) of the lung compared to noncoplanar volumetric modulated arc therapy. Noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system significantly reduced the mean dose (P = .005) and V5 (P = .005) of the normal liver, the mean dose (P = .017) of the spinal cord, V50 (P = .043) of the duodenum, the maximum dose (P = .007) of the esophagus, and V30 (P = .047) of the whole lung compared to volumetric modulated arc therapy. The results indicate that noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system protects the normal liver, stomach, and lung better than noncoplanar volumetric modulated arc therapy and protects the normal liver, spinal cord, duodenum, esophagus, and lung better than volumetric modulated arc therapy. The noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system technique with the arrangement of noncoplanar arcs provided optimal dosimetric gains compared with noncoplanar volumetric modulated arc therapy and volumetric modulated arc therapy, except for the heart. Noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system should be considered in more clinically challenging cases.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call