ABSTRACTBlood collection using dried blood spots (DBS) provides an easier alternative to venipuncture for sample collection, transport, and storage but requires additional processing that can cause variability in results. Whole-blood samples spotted on four DBS devices and respective paired serum samples were tested for antimeasles and antirubella IgG antibody concentrations by enzyme immunoassay. Elution protocols for DBS devices were optimized for comparability relative to serum samples using 12 adult volunteers. Stability of DBS collected on HemaSpot HF was assessed under various temperature conditions (+4, 22 to 25, and 45°C) at six time points (0, 7, 15, 30, 60, and 90 days) in a controlled laboratory setting using six adult volunteers. Devices were shipped and stored for 30 days at four settings with variable temperature and humidity conditions to assess the impact on antibody concentrations. Three DBS devices demonstrated comparable antibody concentrations with paired sera following optimization. Antibodies recovered from DBS were stable for at least 90 days at 4°C and for 30 days at ambient temperature (22 to 25°C) using the HemaSpot HF device. A drastic decline in antibody concentrations was observed at 45°C, resulting in quantitative and qualitative discrepancies by day 7. HemaSpot HF devices shipped to field sites and stored at ambient temperature and humidity resulted in quantitative, but not qualitative, variability. Measurement of antimeasles and antirubella IgG antibodies with DBS devices is an accurate alternative to testing serum, provided elution protocols are optimized. Stability of HemaSpot HF devices at ambient temperature enables broader use in surveys when serum processing and cold storage are not feasible.IMPORTANCE Dried blood spot (DBS) collection offers various advantages over conventional methods of blood collection, especially when collecting and transporting samples for a serosurvey. Yet use of DBS requires additional processing steps in the laboratory that can add to variability in results. We optimized a protocol to elute IgG antibodies against measles and rubella viruses in four DBS devices, demonstrating high concordance with paired venous sera for most devices. Extensive stability studies with various temperature and storage conditions in the laboratory and in the field were conducted using HemaSpot HF DBS devices prior to its use in one of the largest community-based measles and rubella serological surveys in the world.