This systematic review and meta-analysis evaluated the performance of transthoracic echocardiography (TTE) for diagnosis of proximal aortic dissections based on the identification of specific sonographic features. A systematic literature search of major databases was conducted on human studies investigating the diagnostic accuracy of TTE for proximal aortic dissection. The study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. The quality of studies was evaluated using Quality Assessment of Diagnostic Accuracy Studies 2 tool. Data were gathered for the following sonographic findings: intimal flap, tear, or intramural hematoma; enlargement of aortic root or widening of aortic walls; aortic valve regurgitation; or pericardial effusion. Sensitivity, specificity, diagnostic odds ratio, number needed to diagnose values, and likelihood ratios were determined. Fourteen studies were included in our final analysis. More than half of the included studies demonstrated low risk of bias. The identification of intimal flap, tear, or intramural hematoma was shown to have an exceptional ability as a diagnostic tool to rule in proximal aortic dissections. TTE should be considered during the initial evaluation of patients presenting to the emergency department with suspected proximal aortic dissection. Positive sonographic findings on TTE may aid in rapid assessment, coordination of care, and treatment of individuals awaiting advanced imaging.