To investigate the dosimetric variations and radiobiological impacts as a consequence of delivering treatment plans of 3D nature in 4D manner based on the 4D Monte Carlo treatment planning framework implemented on Cyberknife. Dose distributions were optimized on reference 3D images at end of exhale phase of a 4DCT dataset for twenty-five lung cancer patients treated with 60 Gy / 3Fx or 48 Gy / 4Fx. Deformable image registrations (DIR) between individual 3DCT images to the reference 3DCT image in the 4DCT study were performed to interpolate doses calculated on multiple anatomical geometries back on to the reference geometry to compose a 4D dose distribution that included the tracking beam motion and organ deformation. The 3D and 4D dose distributions that were initially calculated with the equivalent path-length (EPL) algorithm (3DEPL dose and 4DEPL dose) were recalculated with the Monte Carlo algorithm (3DMC dose and 4DMC dose). Dosimetric variations of V60Gy / 48Gy and D99 of GTV, mean doses to the lung and the heart and maximum dose (D1 ) of the spinal cord as a consequence of tracking beam motion in deforming anatomy, dose calculation algorithm, and both were quantified by the relative change from 4DMC to 3DMC doses, from 4DMC to 4DEPL doses, and from 4DMC to 3DEPL doses, respectively. Comparing 4DMC to 3DEPL plans, V60Gy / 48Gy and D99 of GTV decreased considerably by 13 ± 22% (mean ± 1SD) and 9.2 ± 5.5 Gy but changes of normal tissue doses were not more than 0.5 Gy on average. The generalized equivalent uniform dose (gEUD) and tumor control probability (TCP) were reduced by 14.3 ± 8.8 Gy and 7.5 ± 5.2%, and normal tissue complication probability (NTCP) for myelopathy and pericarditis were close to zero and NTCP for radiation pneumonitis was reduced by 2.5 ± 4.1%. Comparing 4DMC to 4DEPL plans found decreased V60Gy / 48Gy and D99 by 12.3 ± 21.6% and 7.3 ± 5.3 Gy, the normal tissues doses by 0.5 Gy on average, gEUD and TCP by 13.0 ± 8.6 Gy and 7.1 ± 5.1%. Comparing 4DMC to 3DMC doses, V60Gy / 48Gy and D99 of GTV was reduced by 5.2 ± 8.8 %and 2.6 ± 3.3 Gy, and normal tissues hardly changed from 4DMC to 3DMC doses. The corresponding decreases of gEUD and TCP were 2.8 ± 4.0 Gy and 1.6 ± 2.4%. The large discrepancy between original 3DEPL plan and benchmarking 4DMC plan is predominately due to dose calculation algorithms as the tracking beam motion and organ deformation hardly influenced doses of normal tissues and moderately decreased V60Gy / 48Gy and D99 of GTV. It is worth to make a thoughtful weight of the benefits of full 4D MC dose calculation and consider 3D MC dose calculation as a compromise of 4D MC dose calculation considering the multifold computation time. This article is protected by copyright. All rights reserved.
Read full abstract