Abstract

Background. Proton therapy offers the potential for sparing the normal tissue surrounding the target. However, due to well-defined proton ranges around the Bragg peak, dose deposition is more sensitive to changes in the water equivalent path length (WEPL) than with photons. In this study, we assess WEPL variations caused by breathing-induced motion for all possible beam angles in a series of lung cancer patients. By studying the association between measures for WEPL variation and breathing-induced target dose degradation we aimed to develop and explore a tool to identify beam angles that are robust to patient-specific patterns of intra-fractional motion.Material and methods. Using four-dimensional computed tomography (4DCT) images of three lung cancer patients we evaluated the impact of the WEPL changes on target dose coverage for a series of coplanar single-beam plans. The plans were optimised for the internal target volume (ITV) at the maximum intensity projection (MIP) CT for every 3° gantry interval. The plans were transferred to the ten 4DCT phases and the average reduction in ITV V95 over the ten phases, relative to the original MIP CT calculation, was quantified. The target dose reduction was associated with the mean difference between the WEPL and the phase-averaged WEPL computed for all beam rays across all possible gantry-couch angle combinations.Results. The gantry-couch angle maps showed areas of both high and low WEPL variation, with overall quite similar patterns yet with individual differences reflecting differences in tumour position and breathing-induced motion. The coplanar plans showed a strong association between WEPL changes and ITV V95 reduction, with a correlation coefficient ranging between 0.92 and 0.98 for the three patients (p < 0.01).Conclusion. We have presented a 4DCT-based method to quantify WEPL changes during the breathing cycle. The method identified proton field gantry-couch angle combinations that were either sensitive or robust to WEPL changes. WEPL variations along the beam path were associated with target under-dosage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.