To develop a convenient and simple low-level alpha contamination monitoring method for large quantities of radioactive wastes, a foil-type electret dosimeter was examined. For the electret material, fluoride polymer was used, and the polymer foils weer charged and polarized by applying a high voltage in air while heating at approx. =150/sup 0/C. The surface charge density of the electret foil before and after irradiation was measured by converting to a piezoelectret signal through use of a polyvinylidene fluoride. In the experiments, using a 2.5 kV/mm electric field in electret foils, an electron avalanche effect was produced, and surface charge decay was multiplied. The maximum multiplication factor obtained was approx. =200. The detection limit of alpha surface contamination was confirmed as 10/sup -6/ ..mu..Ci/cm/sup 2/ (3.7x10/sup 2/ Bq/m/sup 2/) for a 5-h irradiation time.