Abstract

More than 50 very large BF3 counters, each approximately 6 ft (180 cm) long and 6 in. (15 cm) in diameter have been made for cosmic-ray monitors. During the fabrication of these counters, the characteristics at varying gas pressures have been studied and the alpha backgrounds of the various metals used for cathodes have been determined. The counters have excellent characteristics at pressures up to 30 cm Hg and perfectly acceptable characteristics to 60 cm Hg pressure. With anode diameter 0.008 in. (0.2 mm) and gas amplification 35, the operating voltage for a filling of 20 cm Hg pressure of pure BF3 is 2800 V; at 30 cm Hg it is 3400 V. Counters with copper cathodes have backgrounds due to residual alpha contamination of about 2 counts/min, and with stainless steel cathodes, about 5 counts/min. Using a BF3–Ar filling a value of 6.30±0.05% has been obtained for the branching ratio of the B10(n,α)Li7 reaction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.