Abstract

A simple and rapid determination of 24 organophosphorus pesticides in agricultural products by using high-purity graphitized carbon black (Supelclean Envi-Carb) cartridge clean-up was developed. Compared to the traditional clean-up method (activated carbon column chromatography or coagulating method), this method saved time and solvent, removed colored materials, and afforded sufficient recovery of 22 organophosphorus pesticides except two polar pesticides, methamidophos and acephate. The detection limit was 0.01-0.1ppm for agricultural products. The recoveries of methamidophos and acephate were 15.8% and 16.7%, while those of the other 22 organophosphorus pesticides were 66.3-88.3%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.