Abstract

Grid simulator can simulate the output of various types of power grid failure to test wind power grid-side equipment, in the design of high-power grid simulator, due to the switching frequency restrictions, will affect the control bandwidth, resulting in the power grid simulator system performance decline. Therefore, the modular multi-level converter (MMC) with higher equivalent switching frequency is used on the inverter side of the grid simulator, and the bridge arm circulation suppression strategy based on the second-order generalized integrator (SOGI) and vector scale integral (VPI) resonant controller is proposed for the internal bridge arm circulation of the converter. Finally, based on RT-LAB, the network simulator controller hardware in the ring (CHIL) experimental platform is built and experimented, the experimental results show that the design of high-power power grid simulator system can simulate the output to obtain the required grid failure.