Abstract
We present the fabrication of a polyimide microcantilever array with integrated gold piezoresistive strain gauges and a thick SU-8 backing for use as a surface stress sensor. The selected polyimide’s low Young’s modulus (1.8GPa) theoretically results in a high sensitivity to changes in surface stress. Electroplated gold contact pads, 1.5μm thick, provide a stable, repeatable surface onto which electrical connections to the fabricated device are made using spring-loaded microprobes. The piezoresistors are found to have a gauge factor of between 4 and 4.5 and a sensitivity to surface stress of 2.1×10−4(N/m)−1.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.