Abstract
Polydiacetylene (PDA) vesicles are of interest as biosensors, particularly for pathogenic bacteria. As part of a food monitoring system, interaction with food sanitizers/surfactants was investigated. PDA vesicles were prepared by inkjet-printing, photopolymerized and characterized by dynamic light scattering (DLS) and UV/Vis spectroscopy. The optical response of PDA vesicles at various concentrations verses a fixed sanitizer/surfactant concentration was determined using a two variable factorial design. Sanitizer/surfactant response at various concentrations over time was also measured. Results indicated that only Vigilquat and TritonX-100 interacted with PDA vesicles giving visible colour change out of 8 sanitizers/surfactants tested. PDA vesicle concentration, sanitizer/surfactant concentration, and time all had a significant (P<0.0001) effect on colour change. As they are highly sensitive to the presence of Vigilquat and TritonX-100, PDA sensors could be used to detect chemical residues as well as for detection of various contaminants in the food industry.