Abstract

A non-evaporable getter (NEG) was tested in the Photon Factory in the pressure range 10 −11 to 10 −9 torr. To test the pumping performance with gas load, one NEG unit was installed in the newly constructed vacuum duct and the other in a fully outgassed duct. The NEGs under both situations worked well under these conditions, as did the distributed ion pumps (DIP). The pumping speed of the NEG for hydrogen seems to be less than the nomical value. An additional pumping is required for pumping methane. A titanium sublimation pump is more effective in pumping carbon monoxide than the NEG.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.