Abstract

Near infrared (NIR) assignment of Isopsoralen was performed using deuterated chloroform solvent and two-dimensional correlation spectroscopy (2D-COS) technology. Yunkang Oral Liquid was applied to study Isopsoralen, the characteristic bands by spectral assignment as well as the bands by interval partial least squares (iPLS) and synergy interval partial least squares (siPLS) were used to establish partial least squares (PLS) model. The coefficient of determination in calibration [Formula: see text] were 0.9987, 0.9970 and 0.9982. The coefficient of determination in cross validation [Formula: see text] were 0.9985, 0.9921 and 0.9982. The coefficient of determination in prediction [Formula: see text] were 0.9987, 0.9955 and 0.9988. The root mean square error of calibration (RMSEC) were 0.27, 0.40 and 0.31 ppm. The root mean square error of cross validation (RMSECV) were 0.30, 0.67 and 0.32 ppm. The root mean square error of prediction (RMSEP) were 0.23, 0.43 and 0.22 ppm. The residual predictive deviation (RPD) were 31.00, 16.58 and 32.41. It turned out that the characteristic bands by spectral assignment had the same results with the chemometrics methods in PLS model. It provided guidance for NIR spectral assignment of chemical compositions in Chinese Materia Medica (CMM).

Highlights

  • Critical quality attribute (CQA) assessment has been highly regarded by International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) and Food and Drug Administration (FDA) in pharmaceutical manufacture process

  • The results showed that optimal model was achieved by synergy interval partial least squares (siPLS) with selected spectral subintervals.[15]

  • Our results proposed that deuterated chloroform was a good solvent for Near infrared (NIR) spectral assignment of Isopsoralen

Read more

Summary

Introduction

Critical quality attribute (CQA) assessment has been highly regarded by International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) and Food and Drug Administration (FDA) in pharmaceutical manufacture process. The NIR wavelength is from 780 to 2500 nm. In this area, the main vibrations of functional groups including a hydrogen atom are observed, such as –CH, –NH, – OH and –SH bonds.[1] For the past few years, NIR has become a powerful analytical technique in quantitative and qualitative analysis.[2] It provided useful functions across a range of application areas, such as pharmacy, chemical industry, food and petroleumeld.[3,4]

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.