Abstract

It is well-documented that subway stations exhibit high fine particulate matter (PM2.5) concentrations. Little is known about the potential of river-tunnels to increase PM2.5 concentrations in subways. We hypothesized a "river-tunnel" effect exists: Stations adjacent to poorly ventilated tunnels that travel beneath rivers exhibit higher PM2.5 concentrations than more distant stations. Accordingly, the PM2.5 concentrations were monitored at stations adjacent to and two- and three-stations distant from the river-tunnel. Multivariate linear regression analysis was conducted to disentangle how proximity to a river-tunnel and other factors (e.g., depth) influence concentrations. Stations adjacent to a river-tunnel had 80-130% higher PM2.5 concentrations than more distant stations. Moreover, distance from a river-tunnel was the strongest PM2.5-influencing factor This distance effect was not observed at underground stations adjacent to a river-bridge. The "river-tunnel" effect explains some of the inter-station variability in subway PM2.5 concentrations. These results support the need for improving ventilation systems in subways.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.