Abstract

The problem of generating minimum-length transition count (TC) tests is examined for combinational logic circuits whose behavior can be defined by an n-row fault table. Methods are presented for generating TC tests of length n+2 and 2n-1 for fault detection and fault location, respectively. It is shown that these tests are optimal with respect to the class of n-row fault tables in the sense that there exist n-row fault tables that cannot be covered by shorter TC tests. The practical significance of these tests is discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.