Abstract

With AlSiC base plate technology for big module, the reliability about thermal cycling due to railway traction is largely improved and the accelerated Power Cycling Test time is increased a lot to reach over 6 months. Then it appears that these failure indicators as; Rth increasing, Vce increasing, or Iges increasing, must be linked to the interface behavior (thermal and mechanical) and the full electrical capabilities of the device to switch on and switch off current and voltage in a converter.This paper discuss about test methodology and protocol of accelerated Power Cycling Test (PCT), including turn off Safe Operating Area (SOA) measurement before and after reliability tests in order to evaluate the influence of the parameters drift Vce, Rth, and gate leakage Iges.Mainly, PCT and SOA results are presented on 1200A-3300V IGBT module with AlSiC base plate materials after a 4000 hours test (376000 cycles) on very hard conditions. It is also shown the SOA capability on one IGBT module with gate leakage failure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.