This paper presents an experimental investigation to study the behavior of Vierendeel Truss used instead of bearing wall in precast construction. The experimental program contains casting and testing (8) R.C wall panels specimens with opening with right angle corner, the dimension of the opening (300*350*75) mm which it is length, width, and thickness. The dimension of the R.C wall panel specimens was (1000*750*75) mm which they are length, width and thickness, respectively and all the specimens contain cantilever portion (100*60*75) mm length width and thickness respectively. In this study the main variable is the type of concrete and the compressive strength. The wall panel specimens were tested with uniformly distributed load with an eccentricity of (67.5) mm. The specimens were simply supported to represent the supports of the truss. The wall panels were divided into (2) groups, the first group is reactive powder concrete with (4) specimens and the second group is high strength self-compacted concrete with (4) specimens. The failure load, load – deflection curves crack pattern was studied. All the panels were deflected in single curvature in the vertical direction of loading. Opening causes concentrated stress at the corners of opening and initiated the cracks and failure.