Sequential extraction procedure (acid extractable, reducible, oxidizable, and residual) proposed by BCR was applied for the determination of trace metals in the River Yesilirmak sediments, Tokat, Turkey. The determination of trace metals in sediment samples was performed by flame atomic absorption spectrometry. The proposed method showed satisfactory recovery, detection limits and standard deviation for trace metals determination in sediment samples. Generally, most of the elements were found in the oxidizable and residual fractions. The total concentrations of trace metals analyzed were found to be (mg/kg) Cu: 37.9, Mn: 392.2, Zn: 126.2, Fe: 3726, and Pb: 29.6, respectively. Results obtained are in agreement with data reported in the literature.