Abstract

In recent years, shorter-chain fluorinated compounds have been manufactured as alternatives to legacy per- and polyfluoroalkyl substances (PFAS) after a global ban on some long-chain PFAS. This study is the first to investigate the degradability of emerging PFAS by an electrochemical plug flow reactor (EPFR). Ten different emerging PFAS, representing classes of fluorotelomer alcohol, perfluoroalkyl ether carboxylate, polyfluoroalkyl ethersulfonic acids, perfluoroalkyl ether/polyether carboxylates, perfluoroether sulfonate, N-alkyl perfluoroalkylsulfonamido carboxylate, fluoroalkyl phosphonic acid, and perfluoro alkane sulfonamide were investigated. The process kinetics was performed. The degradation of parent compounds increased with increasing retention time (RT). At 45.2 min of RT, the degradation of parent compounds ranged between 68%−100% with a current density of 17.2 mA/cm2. A linear increase in pseudo-first order rate constants was observed for all PFAS with increasing current density from 5.7 to 28.7 mA/cm2 (R2 > 0.91). The effect of pH, natural organic matter, and bicarbonate on the degradation, defluorination, and fluorine mass balance are reported. Alkaline pH (11) caused a decrease in degradation for all PFAS. While the presence of natural organic matter (NOM) significantly decreased the degradation and defluorination processes, the presence of bicarbonate at all studied concentrations (25, 50, and 100 mg/L) did not affect the process efficiency. The defluorination reduced to 34% from 81% with 15 mg/L NOM. The unknown/undetected fluorine fraction also increased in the presence of 15 mg/L NOM indicating the formation of NOM-PFAS complexes. Additionally, C2-C8 perfluoro carboxylic acids (PFCAs), one perfluoro sulfonic acid (PFSA), two H-PFCAs, and 4:2 fluorotelomer sulfonate (FTS) were identified as degradation byproducts in suspect screening. The electrical energy per order for PFAS ranged between 1.8 and 19.4 kWh/m3. This study demonstrates that emerging types of PFAS can potentially be degraded using an EPFR with relatively low electrical energy requirements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.