Abstract
After CV measurements of and highly doped Si, using mercury as a Schottky contact, crystal damage on the diode electrode sometimes occurs as can be made visible by selective etching techniques. The presence of this damage appears to be related to the magnitude of the applied bias voltage and to a slight contamination of the mercury with dust particles. The penetration depth has been observed to be in the order of a few hundred nanometers.