Abstract
The application of chemical cleaning for dissolving and removing scale and sludge is being planned in the Japanese pressurized water reactor (PWR) plant in order to maintain high heat transfer performance and to prevent steam generator (SG) tube degradation. In this paper, the effectiveness of the Electric Power Research Institute (EPRI) and German Kraftwerk Union (KWU) processes on the integrity of structural materials other than SG tubes and the comprehensive applicability of chemical cleaning are discussed. The integrity of structural materials such as carbon steel, low-alloy steel and stainless steel was maintained after the EPRI and KWU processes. KWU chemical cleaning tailored for crevice cleaning has been studied to improve its cleaning effectiveness in crevices and to control the corrosion depth of structural materials less than the criterion for corrosion depth.