Abstract
The application of the chemical cleaning process to dissolve and remove scales and sludge by chemicals is being planned at the Japanese pressurized water reactor (PWR) plant in order to maintain a high heat transfer condition and to prevent the steam generator tube degradation. In this paper, fundamental characteristics and cleaning effectiveness of the EPRI process and the KWU process, which are typical cleaning processes, were investigated. Both processes showed a satisfactory cleaning effectiveness for sludges and scales, and the cleaning effectiveness of the standard KWU process was improved by tailoring it to crevice cleaning conditions.
Published Version
Talk to us