Abstract

Conducted immunity tests are always performed by use of Coupling Decoupling Networks (CDN) in laboratories in accordance with the standard EN61000-4-6. However, it is not always possible to use CDNs because of some limitations. If the Equipment Under Test (EUT) has large dimensions or high currents, it is not possible to use CDNs during tests. As a consequence, alternative methods are required in industry. In this paper, we firstly investigated the multi-CDN method which facilitates use of CDNs also for high-current EUTs by splitting mains current into several pieces that one CDN can handle. We also investigated simple wire-windings instead of cumbersome injection clamps to be applied to thick cables or cables in narrow places as an alternative to standard laboratory methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.