Conducted immunity tests are always performed by the use of CDNs in laboratories in accordance with the standard EN61000-4-6. However, it is not always possible to use CDNs because of some limitations. If the EUT (Equipment Under Test) has large dimensions or high currents, it is not, most of the time, possible to send it to an EMC laboratory or to use CDNs during the test. As a consequence, usage of BCI probes is inevitable in industry. In this paper, we compared the laboratory setup installed with CDNs and alternative setups installed directly on mains without any CDNs in terms of loop impedances and injected loop currents. We also established a link based on the loop impedances and the injected currents on the test loops between the two setups. Finally, a first serious step was taken to establish the fundamentals of alternative conducted immunity tests based on the impedance measurements of test loops for industry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.