Abstract
ABSTRACT In this paper a new, improved induction motor control topology is proposed which allows for continuous, disturbance-free operation of the drive with a failed short-circuited switch in one leg of the inverter. The analysis of this control strategy and the computer simulation are explored. The experimental results from hardware are attached to verify the simulation results. A complete control strategy combined with short-circuit fault and open-circuit fault is also included.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.