This study investigated indoor radon concentrations in modern residential buildings in the Cold Area and Severe Cold Area in China. A total of 19 cities covering 16 provinces were selected with 1,610 dwellings measured for indoor radon concentration. The arithmetic mean and geometric mean of indoor radon concentration were 68 Bq m-3 and 57 Bq m-3, respectively. It was found that indoor radon concentrations were much higher in the Severe Cold Area than those in the Cold Area. The indoor radon concentrations showed an increasing trend for newly constructed buildings. It was estimated that the average effective dose from inhalation of indoor radon is 2.15 mSv and 1.60 mSv for the Severe Cold Area and Cold Area, respectively. The more and more rigid energy-saving design for residential buildings in the Severe Cold Area and Cold Area has an obvious impact on the increased trend of indoor radon due to extremely low air exchange rate in China.