Osseointegration is defined as the direct structural and functional connection between neo-formed bone and dental implants. Among the parameters suggested to predominantly influencing the establishment of a successful osseointegration is the quality of the implant surface, which may enhance the strength and speed of this biomechanical process. The purpose of this study was to evaluate the ability of a novel laser-treated surface, compared to sandblasted, large-grit, acid-etched (SLA) surfaces, to enhance and accelerate implant integration in delayed implant placement.Methods: Thirty patients with two missing posterior teeth were enrolled in this study. Each patient received, at a randomly allocated site, an implant with a conventional SLA surface, and at a second site, an implant with laser-textured surface. A total of 60 tissue-level implants were subsequently placed. Implant stability (ISQ) was measured using resonance frequency analysis (RFA). ISQ was assessed at baseline (T0), 8 weeks (T1), and 12 weeks (T2) following implant placement. Results: There was a statistical difference in implant stability between laser-textured and SLA group at 12 weeks postoperatively. Implant stabilization showed a successful osseointegration with both surface types. Both laser and SLA surface treatments had positive impacts on implant stabilization following delayed placement. Laser-treated surfaces presented higher values of osseointegration at 3 months postoperatively.