This report aims to propose and present an evaluation of a robust pencil beam scanning proton multi-field optimized treatment planning technique for postmastectomy radiation of breast cancer patients with implanted tissue expanders containing an internal metal port. Field-specific split targets were created for optimization to prevent spots from traveling through the metal port, while providing uniform coverage of the target with the use of a multi-field intensity modulated optimization approach. Two beam angles were strategically selected to provide complementary target coverage and plan robustness. The plan was compared with an independently developed photon plan and evaluated for robustness with respect to isocenter shifts, range shifts, and variation of the water-equivalent thickness of the port. The proton plan resulted in clinically acceptable target coverage and dosage to neighboring normal tissues. The D95% coverage was 95.3% in the nominal proton plan, with a worst-case coverage of 90.1% (when considering 0.3 cm isocenter shifts combined with 3.5% range uncertainty), and the coverage varied less than 1% under a hypothetically extreme variation of the port density. The proton plan had improved dose homogeneity compared with the photon plan, and reduced ipsilateral lung and mean heart doses. We demonstrated that a practical, field-specific intensity-modulated proton therapy (IMPT) optimization technique can be used to deal with the challenge of metal port in breast cancer patients with tissue expanders. The resulting proton plan has superior dosimetric characteristics over the best-case scenario photon plan, and is also robust to setup and proton range uncertainties.