The modular multilevel converter (MMC) is recognized as one of the promising converters for the electrification of ships and railways. Among different energy conversion stages, the MMC-based rectifier should realize stable DC output voltage and accurate input current control. However, output DC-bus voltage sensors must be installed, which are costly and bulky. This paper presents a simple but effective control method for the MMC-based rectifier, removing the traditional output DC-bus voltage sensor. An accurate evaluation model of DC-bus voltage is developed as well as the implementing method. Meanwhile, a safe and fast pre-charging scheme is presented for the MMC-based rectifier without output voltage sensors. The fault-tolerant capability of the proposed method when the failure of the output DC-bus voltage sensor occurs is examined. Simulated and testing results demonstrate that the proposed method presents not only excellent steady-state and dynamic performance but also strong fault-tolerant capability. The proposed evaluation model for DC-bus voltage has a high accuracy with an error of less than 1%. Besides, the pre-charging time is less than 0.5 s using the proposed sensorless control.