Building sector contributes 40% of total energy consumption. In line with this, passive design strategy should be taken as an essential consideration to bring occupants comfort both thermally and visually. Besides, related to human health, one of the factors that the designer is encouraged to fulfill is the proportional amount of daylight that penetrates the building’s room. The passive strategy to optimize the daylight performance can be approached both from the building orientation and the shading system. This paper will computationally compare the different shading systems from vertical and horizontal louver, perforated metal sheets, and expanded metal shading, aiming to investigate the desirable shading-related design solution for the given condition. The simulated room is virtually situated in three different sun positions: Birmingham, United Kingdom, Jakarta, Indonesia, and Sydney, Australia. The metrics used in this experiment are Useful Daylight Illuminance (UDI). The Rhinoceros and Grasshopper were used to model the intended simulated room, while Ladybug and Honeybee were used to undergo environmental analysis. The results show that the vertical louver LV performs better in the three regions than the rest three compared shading. The experiment results are expected to give an overview which of which is fit for the situation.