Using ex vivo microscopy, virtual pathology can improve histological procedures by providing pathology images in near real-time without tissue destruction. Several emerging and promising approaches leverage fast-acting small-molecule fluorescent stains to replicate traditional pathology structural contrast, combined with rapid optical sectioning microscopes. However, several vital challenges must be addressed to translate virtual pathology into the clinical environment. One such challenge is selecting robust, reliable, and repeatable staining protocols that can be adopted across institutions. In this work, we addressed the effects of dye selection and staining protocol on image quality in rapid point-of-care imaging settings. For this purpose, we used structured illumination microscopy to evaluate fluorescent dyes currently used in the field of ex vivo virtual pathology, in particular, studying the effects of staining protocol and temporal and photostability on image quality. We observed that DRAQ5 and SYBR gold provide higher image quality than TO-PRO3 and RedDot1 in the nuclear channel and Eosin Y515 in the extracellular/cytoplasmic channel than Atto488. Further, we found that TO-PRO3 and Eosin Y515 are less photostable than other dyes. Finally, we identify the optimal staining protocol for each dye and demonstrate pan-species generalizability.