A PIN-diode-based 1D x-ray camera and a scintillator-based 1D x-ray camera, both with a microsecond to submicrosecond time resolution, have been developed to perform time-resolved imaging of transient, low-intensity, suprathermal x-rays associated with magnetohydrodynamic instabilities disrupting a plasma jet. These cameras have a high detection efficiency over a broad x-ray band, a wide field of view, and the capability to produce >50 time-resolved frames with a ≤1 μs time resolution. The x-ray images are formed by a pinhole or by a coded aperture placed outside a vacuum chamber in which the plasma jet is launched. The 1D imaging shows that the location of the x-ray source is either a few centimeters away from an inner disk electrode or near a spatially translatable metal frame that is 30-40cm away from the electrode. Compared to a pinhole, a coded aperture increases the signal collection efficiency but also introduces unwanted artifacts.