Some years ago terminal pumping for the gas stripper system at the 3 MV Lund Tandem Pelletron accelerator was installed and charge state distribution measurements using the new installation were reported. Since then, new modifications of the mechanical design of the stripper system have been made. The results of pressure profile measurements as well as the results of charge state distribution measurements in a N 2 and Ar gas stripper at different, new geometrical modifications of the stripper system using C, Be, Al and Cl ion beams are reported. A comparison between pressure profiles obtained for different geometries shows a clear improvement of the vacuum conditions outside the stripper housing for the smallest conductance pipes between the stripper system and the accelerator tubes. These improvements are also well reflected in the charge state distribution measurements, as a higher mean charge state is obtained under the same vacuum conditions in the accelerator tubes for the improved stripper system in comparison with the former mechanical design.