BackgroundA major goal of contemporary obstetrical practice is to optimize fetal growth and development throughout pregnancy. To date, fetal growth during prenatal care is assessed by performing ultrasonographic measurement of two-dimensional fetal biometry to calculate an estimated fetal weight. Our group previously established two-dimensional fetal growth standards using sonographic data from a large cohort with multiple sonograms. A separate objective of that investigation involved the collection of fetal volumes from the same cohort. ObjectiveThe Fetal 3D Study was designed to establish standards for fetal soft tissue and organ volume measurements by three-dimensional ultrasonography and compare growth trajectories with conventional two-dimensional measures where applicable. Study DesignThe NICHD Fetal 3D Study included research-quality images of singletons collected in a prospective, racially and ethnically diverse, low-risk cohort of pregnant individuals at 12 U.S. sites, with up to five scans per fetus (N=1,730 fetuses). Abdominal subcutaneous tissue thickness was measured from two-dimensional images and fetal limb soft tissue parameters extracted from three-dimensional multiplanar views. Cerebellar, lung, liver and kidney volumes were measured using virtual organ computer aided analysis (VOCAL). Fractional arm and thigh total volumes, and fractional lean limb volumes were measured, with fractional limb fat volume calculated by subtracting lean from total. For each measure, weighted curves (5th, 50th, 95th percentiles) were derived from 15-41 weeks’ using linear mixed models for repeated measures with cubic splines. ResultsSubcutaneous thickness of the abdomen, arm, and thigh increased linearly, with slight acceleration around 27-29 weeks. Fractional volumes of the arm, thigh, and lean limb volumes increased along a quadratic curvature, with acceleration around 29-30 weeks. In contrast, growth patterns for two-dimensional humerus and femur lengths demonstrated a logarithmic shape, with fastest growth in the 2nd trimester. The mid-arm area curve was similar in shape to fractional arm volume, with an acceleration around 30 weeks, whereas the curve for the lean arm area was more gradual. The abdominal area curve was similar to the mid-arm area curve with an acceleration around 29 weeks. The mid-thigh and lean area curves differed from the arm areas by exhibiting a deceleration at 39 weeks. The growth curves for the mid arm and thigh circumferences were more linear with some decelerations. Cerebellar two-dimensional diameter increased linearly, whereas cerebellar three-dimensional volume growth gradually accelerated until 32 weeks and then decelerated. Lung, kidney, and liver volumes all demonstrated gradual early growth followed by a linear acceleration beginning at 25 weeks for lungs, 26-27 weeks for kidneys, and 29 weeks for liver. ConclusionGrowth patterns and timing of maximal growth for three-dimensional lean and fat measures, limb and organ volumes differed from patterns revealed by traditional two-dimensional growth measures, suggesting these parameters reflect unique facets of fetal growth. Growth in these three-dimensional measures may be altered by genetic, nutritional, metabolic or environmental influences and pregnancy complications, in ways not identifiable using corresponding two-dimensional measures. Further investigation into the relationships of these three-dimensional standards to abnormal fetal growth, adverse perinatal outcomes, and health status in postnatal life is warranted.