The aim of the study was to evaluate, in an international collaboration, three lyophilized intravenous immunoglobulin (IVIG) preparations for their suitability to standardize and control haemagglutination testing for anti-A and anti-B in IVIG products. Twenty-three laboratories tested candidate IVIG reference reagents consisting of a Positive control (07/306), a Negative control (07/308), and a specifically formulated Limit preparation (07/310) to define the maximum (e.g. pharmacopoeial) limits of anti-A and anti-B in IVIG products, where limits are applicable. Laboratories performed direct haemagglutination using papain-treated erythrocytes and/or indirect antiglobulin tests. For both methods, there was up to 16-fold variation in anti-A and anti-B titres, although there was good agreement over a two-fold titre range for anti-A and anti-B between laboratories for both 07/306 and 07/310 using the direct method. Comparative titration data for 07/306 and 07/310 indicated that the use of a 'Limit' reference reagent would facilitate identification of higher titre batches when the direct haemagglutination method is used. The establishment of preparations 07/306, 07/308 and 07/310 as reference reagents by the World Health Organization will facilitate global standardization of haemagglutination tests for anti-A and anti-B, ensure that such tests are sufficiently sensitive and specific, and facilitate identification of batches that exceed maximum recommended levels of anti-A and anti-B. The Commission of the European Pharmacopoeia and the United States Food and Drug Administration have adopted the same reference reagents including the maximal specifications defined by preparation 07/310.