Transversal and longitudinal homogeneity of Bi-2223/Ag tapes made by a tape-in-rectangular tube process with high filament aspect ratio was studied. Spatially resolved transport measurements (“magnetic knife”), Hall probe measurements and local V– I measurements were used to obtain the I c distribution across and/or along the tape sample. The I c distribution in the width of the filaments shows a minimum in the filaments centre and a maximum is measured near the filament edges. A periodical variation of longitudinal I c values is observed by local V– I and by Hall probe measurements. Transversal and longitudinal filaments cross-sections were obtained and compared to transport critical currents.