AbstractExperiments were carried out to investigate the flow pattern, average void fraction, and pressure drop of an upward air‐water two‐phase flow in vertical tubes of 25‐mm inside diameter with wire coils of varying wire diameter, pitch, and number of coils in cross section. Five kinds of flow patterns—bubble, slug, churn, semiannular, and annular flow—were defined based on the observation of flow behavior in the experiments. At higher water flowrates, the bubble‐to‐slug transition occurred at lower air flowrates in tubes with wire coils than in smooth tubes. The average void fraction was found by using the drift flux model. Further, the experimental results of the friction pressure drop were compared with the Lockhart‐Martinelli correlation. As a result, a correlation with the constant C in Chisholm's equation was obtained as a function of the wire coil pitch‐to‐diameter ratio. © 2002 Wiley Periodicals, Inc. Heat Trans Asian Res, 31(8): 639–651, 2002; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/htj.10066