Abstract
An experimental study has been carried out to clarify the characteristics of the void fraction and liquid film thickness of air-water two-phase flow in vertical tubes of 25 mm inside diameter with wire coil of varying wire diameter and pitch. Flow pattern in the experiment of average void fraction and local void fractrion distribution in a cross section is bubble flow, and liquid film thickness is in the region of semi-annular and annular flow. It is clarified from these experiments that the average void fraction in tubes with a wire coil is lower than that of the smooth tube and decreases with the wire diameter owing to the centrifugal force of swirl flow which concentrates bubbles at the center of the tube, and the liquid film thickness between the wire coil is uniformed with the decrease of the pitch of wire coil and that liquid film becomes thicker after the passage of wire coil with the increase of the wire diameter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.