This paper describes the development and validation of a competitive, polyclonal antibody enzyme-immunoassay (EIA) for the measurement of salmon and trout insulin-like growth factor-II (IGF-II). A polyclonal antiserum was raised against a synthetic peptide epitope, corresponding to amino acid residues 1–9 of the N-terminus of mature Atlantic salmon ( Salmo salar) IGF-II. The antiserum was purified by hydrophobic charge induction chromatography (HCIC). The partially purified immunoglobulins were used in an enzyme-immunoassay system (EIA) resulting in a highly specific assay for salmon IGF-II with cross-reactivity of less than 0.01% for recombinant salmon IGF-I and recombinant salmon growth hormone (GH), and 5.57% for salmon insulin (sIns). The recombinant salmon IGF-II (rsIGF-II) standard curve limit of detection was 1.37 ng/ml with an EC 50 of 44.97±0.82 ng/ml. Intra- and interassay coefficients of variation were determined at 7.47% ( n=15) and 7.42% ( n=15), respectively. Added rsIGF-II was adequately recovered from acid-treated Atlantic salmon and rainbow trout ( Oncorhynchus mykiss) plasma samples. Parallel dose–response inhibition curves were demonstrated for the plasma of both fish species tested. Circulating IGF-II levels of 22.26±2.66 and 18.24±1.43 ng/ml were determined for acid-treated plasma of normal adult Atlantic salmon and rainbow trout, respectively. This EIA should prove to be useful in the study of factors which influence circulating plasma levels of IGF-II in these fish species.