Objective: To explore an adequate treatment method and provide a better irradiation mode for upper, and mid, esophageal carcinoma radiotherapy by comparing the dose distributions of six different semi-field radiotherapy options.Methods: Twenty patients with upper, and mid, esophageal carcinoma were selected for six treatment options, three [Options D-F] were semi-field irradiation: Option A-conventional 5-field three-dimensional conformal radiation therapy (3D-CRT); option B-conventional 5-field intensity modulated radiation therapy (IMRT); option C-conventional 3-field IMRT; option D-5-field IMRT (upper target) and 3-field conformal radiation therapy (lower target); option E-5-field IMRT (upper target) and 3- field IMRT (lower target); and, option F-5-field IMRT (upper target) and 5-field IMRT (lower target). Dose distribution in the target areas and dose distribution in normal tissue were compared for the six options.Results: Target coverage by the semi-field techniques was effective in a comparison of the six options. Lung low-dose area and mean lung dose (MLD) were lower in Options D and E. Option E conformal index in was higher than Option D.Conclusion: Options D and E appear to be two relatively advantageous options as they allow effective delivery of the prescribed dose to the target volumes while minimizing the lung tissue exposure to low doses.