Serum levels of C3, C4, factor B, properdin, total hemolytic complement and alternative-pathway hemolytic activity were measured before and after double-blind food challenge in 23 children with impressive histories of adverse reactions to foods. The 23 subjects had 11 positive food challenges and 12 negative food challenges. Nine patients with reagin-mediated positive food challenges showed increases in all six complement assays after double-blind food challenge, while the group with negative food challenges showed decreases in five of the six assays. The difference between the two groups for complement changes after double-blind food challenge was significant only for the alternative-pathway assay. Individual subject analysis revealed markedly heterogeneous changes in direction and magnitude within both groups for all complement assays. Therefore, it is concluded that measurement of serum complement levels is not a useful test for the clinical evaluation of a patient with suspected food sensitivity.