The separation of undesired product-related impurities often poses a challenge in the purification of protein therapeutic species. Product-related impurity species, which may consist of undesirable isoforms, aggregated, or misfolded variants of the desired monomeric form of the product, can be challenging to remove using preparatory scale chromatographic techniques. When using anion exchange chromatography to remove undesirable product-related impurities, the separation can be highly sensitive to relatively small changes in the chromatography operating conditions, including changes to buffer solution pH, buffer solution conductivity protein loading, and operating temperature. When performing difficult separations, slight changes to the chemical and physical properties of the anion exchange adsorbent lot may also impact the separation profile. Such lot-to-lot variability may not be readily measurable by the adsorbent manufacturer, since variability can be highly dependent on a specific protein separation. Consequently, manufacturers of chromatographic adsorbents may not be able to control adsorbent lot to lot variability tightly enough to prevent differences from occurring when performing difficult product-related separations at the preparatory scale. In such cases, it is desirable to design a chromatography step with a control strategy which accounts for adsorbent lot to lot variability in the separation performance. In order to avoid the undesired changes to process consistency and product quality, a proper adjustment of the column operating conditions can be implemented, based on the performance of each adsorbent lot or lot mixture. In this work, we describe how the adjustment of the column buffer solution composition can be used as a design space based-control strategy used to ensure consistent process performance and product quality are achieved for an anion exchange chromatography step susceptible to adsorbent lot to lot performance variability. In addition, a “use test” is described that can be employed to determine the optimal buffer solution compositions for different anion exchange adsorbent lots based on the retention volume of the therapeutic protein during a gradient elution.
Read full abstract