Accurate calculation of the flux and the magnetic field distribution of fractional slot concentrated winding permanent magnet synchronous motor (FSCW PMSM) is the basis for motor performance analysis, and rapid calculation is key. In this paper, to solve the problem of difficult modeling and accuracy guarantee of the flux linkage differential method, a method is proposed to calculate the flux and the no-load back EMF by the slotless subdomain model. By introducing the leakage flux calculation link, the calculation accuracy is improved, the analytical method results are compared with the finite element method results, and the effectiveness of the proposed method is verified. On this basis, the nonlinear variations of the magnetic field and the no-load back EMF with rotor permeability are determined, and the influence mechanism of rotor length and rotor permeability on the main magnetic circuit is revealed. Finally, an experiment of the prototype is carried out, and the correctness and accuracy of the analytical method and the finite element method is verified by comparing with the experimental results.