Abstract

In this paper, a z-axis displacement sensor based on Total-Internal Reflection and Surface Plasmon Resonance in heterodyne interferometry is proposed. The sensing unit is composed of a parallelogram prism, i.e. elongated prism, and a displacement probe. One side surface of the elongated prism was coated with a 2 nm Ti-film and a 45.5 nm Au-film, but the other side surface of that were not coated with metal films. The z-axis displacement sensor is with high sensitivity and resolution due to multiple attenuated total reflections and total internal reflections effects. Besides, we can obtain the results of the experiment in a distant place by uses of the USB data acquisition card (DAQ card) and a ZigBee module. In fact, the displacement resolution of the z-axis displacement meter can reach sub-nanometer by numerical simulation. The small-displacement sensor has some merits, e.g., in real-time test, easy operation, high measurement accuracy, high resolution, etc.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.