Abstract

In this paper, a new type small-angle sensor based on multiple total internal reflections and attenuated total reflections in heterodyne interferometry is presented. The small-angle sensor is designed as a reflective elongated prism that is made of BK7 glass. The shorter-side surface of the reflective elongated prism was coated with 2nm Ti-film and 45.5nm Au-film, but the longer-side surface of that was not coated with metal films. With the new type small-angle sensor, the small rotation angle can be obtained only by measuring the phase difference between the p-and s-polarization lights due to the multiple attenuated total-internal reflections (MATRs) and total-internal reflections (TIRs) effects. Its angular resolution can reach 0.000000295 radian at least. The new type small-angle sensor has some merits, e.g., high resolution, high sensitivity, stability, and in real-time test, etc.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.