Abstract

A quantitative schlieren method is described which uses photomultiplier detection of the deflection of a narrow gas-laser beam to obtain a close approximation to a point measure of density gradient. This method is very sensitive to rapid density changes (a gradient of 5×10−5 g/liter·mm can be detected in argon) and laboratory relaxation times as short as 0.2 μsec can be measured in the shock tube. The application of this technique to studies of vibrational relaxation is discussed in detail, and the method is compared with the integrated schlieren of Resler and Scheibe for this application. This technique has been applied to a shock-tube study of the vibrational relaxation of mixtures of D2 in Ar with the results, in atmosphere·seconds, Pτ = (2.7±0.3)×10−10 exp[(110.5±1.5)/T⅓], (1100°—3000°K) for pure D2, and Pτ = (1.0±0.7) × 10−9 exp[(118±10)/T⅓], (1600°—3000°K) for D2 dilute in Ar. The experimental results are in serious disagreement with both the correlation scheme of Millikan and White and the SSH theory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.